12 Channel ECG Holter Monitor TLC5000
The Features of Recorder
With advanced design and technology, the recorder can work stably, dependable and durable.
Be provided with the capability of anti-jamming and shock-pro.
Small volume with OLED screen. The resolution is 160*128.
Be provided with functions of waveform preview, record review and event marking.
Accurate record of the start time of the data sampled owing to the real time clock of itself.
Avoid damage owing to the repeating inserting and pulling out by using the inbuilt TF card to storage the data.
The maximum capability can be 2GB, so the original data can be saved perfectly by no compression.
The average review time of single case can be less than 40 seconds by using interface of USB 2.0.
Record waveform details inextenso by the design of high precision and sampling frequency.
Record the state of pacemaker exactly by higher sampling frequency.
International standard of 12 leads. Record 24-hour DECG with the same standard of the ECG.
The Features of Software
Quick and accurate analysis system.
With 12 leads synchro analysis , QRS search can be more exactly.There are more than 10 templates as atrial premature beat module, ventricular
premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicate User-defined templates could almost identify every kind of pathologic waveforms.
Optional main channel.
Agile and exact "Atrial Fibrillation" analysis.
The function of pacing analysis could analyze all pacemakers.
Many pacine modules have been added.
Any period of single lead or 12-leads ECG can be reviewed at any time with the function of fast waveform review and analysis.
The types of the analysis system of HR variability include five minutes of short ECG and one hour or 24-hour of long ECG.
Print report expediently.
Perfect function of case management.
With the function of ST segment analysis and general load of the disorder of the heart muscle, the physician can judge a disease or disorder of the heart muscle generally.
"Sleep breath pause syndrome analysis", the physician could print sleep asphyxia analysis report and diagnose.
"HRT" analysis, when the adjustable function is natural, this transitory change will be represented by the form of HRT immediately.
15."T Wave alternation" analysis is a important index on judging and preventing Arrhythmia .
The report has more reference value with the functions of VCG, VLP, TVCG and QTD analysis.
Specifications
Number of channels: 12 channels;
Sampling rate:10000Hz;
Sampling accuracy:12bit;
Recording time : 24 h;
Power: 2 batteries in size 5;
Interface: USB2.0;
Scale voltage:1mV±5%;
Standard Sensitivity:10mm/mV±5%;
Noise level:≤30μV;
CMRR:≥60dB;
Feathers of low frequency : Time constant>3.2s;
Scan speed:25mm/s±5%;
Enduring polarization voltage:±300mV;
Least measure signal : 50 µV p-p;
Product safety type : Type B (Internally powered);
Size:111mm(L)*60mm(W)*25mm(H);
Net Weight: 102g (Without battery).
Standard Configuration
No. |
Contents |
Qty |
1 |
Digital ECG Recorder |
1 |
2 |
Patient Cable |
10 |
3 |
USB Cable |
1 |
4 |
Leather Pouch |
1 |
5 |
ECG Eletrodes |
1 |
6 |
User Manual |
1 |
7 |
Software |
1 |
8 |
Softdog |
1 |