FEATURE Complete Intellectual Design Automatic Exposure Control (AEC) detects the lacteal gland area with precision and controls the tube voltage and the mAs value automatically.
Flexible automatic compression makes it possible to automatically adjust the compression force on the breast to an appropriate value, which makes it possible to improve patient comfort.
Optimal Image Quality In order to obtain high resolution image at lower dose, a variety of characteristic curves were validated by clinical which were assembledto enhance the contrast grade and reduce the impulse noise of image, this is the best way for mammary screening.
Prospective X-ray Tube Technology with Tungsten Target
High X-ray energy
Strong penetrability
Low dose, high quality image
Trend of mammography technology
New Generation of Flat PanelDetector(FPD)
240 mm × 300 mm, full-field FPD
High limiting resolution
Wide dynamic range
Low dose
Isocentric Rotation Full of humanity design,downy lines as well as smooth the appearance of this Digital Mammography even more warmth. The examination position was the center of rotation, which is a Ergonomically Designed and fully meet the requirements of clinical breast examination.
MAIN PART Main Unit Flat Panel Detector High Voltage Generator X ray Tube Assembly Collimator Image Workstation
High Voltage Generator:VMX40P5X4297 Nominal Mains Voltage: 200-240 V AC Output Power: 5 kW mA Range: 10 ~ 160 mA kV Range: 20 ~ 40 kV mAs Range: 2.5 ~ 630 mAs ms Range: 16 ~ 10000 ms Autocorrection: YES Error Log: YES Automatic Overload Protection: YES
X-ray Tube:C339V(XM15T) Maximum Tube Current: 160 mA Focal Spot: Small Focus: 0.1 mm Large Focus: 0.3 mm Anode Angle: 15° Anode Marerial: RT-TZM/tungsten target Anode Speed: 10000 rpm Input Energy(at 0.1s)Small Focus: 4 kW Large Focus: 16 kW Operating Tube Voltage: 20 ~ 49 kV Anode Heat Storage Capacity: 300 Khu
C-Arm C-Arm Rotation Mode: Motor, 10°/s C-Arm Rotation Range: -165°~+180° C-Arm Vertical motion Mode: Motor, 35 mm/s C-Arm Vertical motion Range: 65~140 cm Armrests that provide the sense of security are mounted so as to decrease patient's unpleasantness at the positioning.
Software System Image Browser: Image selection, image processing(crop, zoom, grayscale adjustment, rotate, flip, tag, window layout etc.) Image Post-Processing: Image enhancement, tissue equalization, noise reduction, gray level stretching Image Output: Support for Laser printer output, laser camera output, Dicom interface and hard disk Data Management: Data deletion, statistics, edit, backup and restore Other features: Detector calibration procedures, failure report function, worklist module, dynamic password maintenance, machine using period limiting setting ,report writing and printing etc.
PC System Display: Lenovo LCD, LT1953wA, 19inch CPU:≥Intel Core i3-3240 RAM: 4GB DDR3 Hard Disk: 500GB Graphics card: Integrated graphics card CD-ROM: DVD-R/W Net Card: 100/1000Mbits NIC USB: 6 USB2.0 Extend: 2PCI+1PCIE+1PCIE*16 OS: WINDOWS 7 32bit