Pulse Vacuum Autoclave
(Single Door or Double Door ,Capacity from 0.25m³ to 2.5m³)
1.MAIN PARAMETERS
*Pulse Vacuum Sterilizer AJ-MD25 (Single Door or Double Door)
Capacity: 0.25m³
Inner Chamber Dimension (L*W*H): 800*600*600mm
Outer Dimension (L*W*H): 1100*1300*1700mm
Steam Pressure and the Consumption: 0.4-0.8Mpa 15KG
Water Source Pressure and the Consumption: 0.15-0.3Mpa 35KG
Power: 2+24KW
Net Weight: 900Kg
Design Pressure: 0.25Mpa
Design Temperature: 139ºC
*Pulse Vacuum Sterilizer AJ-MD36 (Single Door or Double Door)
Capacity: 0.36m³
Inner Chamber Dimension (L*W*H): 1000*600*600mm
Outer Dimension (L*W*H): 1300*1300*1700mm
Steam Pressure and the Consumption: 0.4-0.8Mpa 20KG
Water Source Pressure and the Consumption: 0.15-0.3Mpa 40KG
Power: 2+24KW
Net Weight: 1000Kg
Design Pressure: 0.25Mpa
Design Temperature: 139ºC
*Pulse Vacuum Sterilizer AJ-MD60 (Single Door or Double Door)
Capacity: 0.6m³
Inner Chamber Dimension (L*W*H): 1200*610*910mm
Outer Dimension (L*W*H): 1500*1350*1950mm
Steam Pressure and the Consumption: 0.4-0.8Mpa 30KG
Water Source Pressure and the Consumption: 0.15-0.3Mpa 45KG
Power: 3+36KW
Net Weight: 1400Kg
Design Pressure: 0.25Mpa
Design Temperature: 139ºC
*Pulse Vacuum Sterilizer AJ-MD80 (Single Door or Double Door)
Capacity: 0.8m³
Inner Chamber Dimension (L*W*H): 1500*610*910mm
Outer Dimension (L*W*H): 1800*1350*1950mm
Steam Pressure and the Consumption: 0.4-0.8Mpa 40KG
Water Source Pressure and the Consumption: 0.15-0.3Mpa 50KG
Power: 3KW
Net Weight: 1600Kg
Design Pressure: 0.25Mpa
Design Temperature: 139ºC
*Pulse Vacuum Sterilizer AJ-MD120 (Single Door or Double Door)
Capacity: 1.2m³
Inner Chamber Dimension (L*W*H): 1500*680*1180mm
Outer Dimension (L*W*H): 1790*1450*1950mm
Steam Pressure and the Consumption: 0.4-0.8Mpa 48KG
Water Source Pressure and the Consumption: 0.15-0.3Mpa 55KG
Power: 4KW
Net Weight: 1800Kg
Design Pressure: 0.25Mpa
Design Temperature: 139ºC
*Pulse Vacuum Sterilizer AJ-MD150 (Single Door or Double Door)
Capacity: 1.5m³
Inner Chamber Dimension (L*W*H): 1900*680*1180mm
Outer Dimension (L*W*H): 2190*1450*1950mm
Steam Pressure and the Consumption: 0.4-0.8Mpa 55KG
Water Source Pressure and the Consumption: 0.15-0.3Mpa 60KG
Power: 4KW
Net Weight: 2000Kg
Design Pressure: 0.25Mpa
Design Temperature: 139ºC
*Pulse Vacuum Sterilizer AJ-MD200 (Single Door or Double Door)
Capacity: 2.0m³
Inner Chamber Dimension (L*W*H): 1700*1000*1200mm
Outer Dimension (L*W*H): 2000*1850*2000mm
Steam Pressure and the Consumption: 0.4-0.8Mpa 65KG
Water Source Pressure and the Consumption: 0.15-0.3Mpa 65KG
Power: 4.5KW
Net Weight: 2500Kg
Design Pressure: 0.25Mpa
Design Temperature: 139ºC
2. APPLICATION
The cabinet utilizes the physical characteristics of the saturated steam, which would release large amounts of latent heat and humidity during condensation, and with a period of time to keep the object at high temperature and most condition, the main protein of the bacteria would be solidified so that the bacteria can be killed.
The device is widely used in pharmaceutical, medical, scientific and other industries for the high temperature sterilization, cooling and drying process to the biological products, medical devices, sterile clothing, tools, utensils, media, and the other items.
3. CHARACTERISTICS
The main body is with horizontal rectangle double layer structure, the inside chamber is made of SUS30408 or SUS31608 stainless steel, the outer layer is made of the brushed decorative sheet, and the there is motorized door or sliding door for choose, pneumatic sealing, and the double door interlocking are strictly in accordance with the GSSD required.
The control system: adopt the Siemens PLC and Siemens touch screen.
The piping system: Adopt with the reliable Germany Burkert or pneumatic angle type valve, water ring vacuum pump and 1.22um high efficiency sterile medical grade filters, the pipe clamp adopts the quick connectors, the piping and the related spares are all according to the sanitation standard.
4. CHARACTERISTICS OF SOFTWARE
·With Germany Simens PLC platform independent research and development, human-Machine Interaction, convenient for operation.
·Software design and manufacture products in strict accordance with the technical requirements for the sterilization process.
·The Operating authority is divided into three levels to the manager, the technologist, and the operators.
· Program interlocked, by the program is running, the sealing door can not be open.
·All the alarm and the technical figures can be recorded and print.
·If the inner chamber is higher than the safety pressure, the door can not be open.
·Perfect product safety protection measures,4 level emergency treatment of abnormal state.
5. STERILIZING CYCLES
The sterilization cycle to the solid objects applied to the instruments, dressings, utensils and other items.
Why choose us?
1.Key parts of our products are made of imported equipments. Some key parts are made in Germany and Japan.
2.We offer one year warranty, Provide spare parts with shipping for free within one year and just Charge the cost of accessories once after the warranty period.
3.Our company is certified company by SGS.
4.Our company is senior member of China Medical Device Industry Association.