Anaesthesia Machine
NewBright A4
ADVANCED DESIGN & MONITORING
Large screen high-definition TFT wide viewing angle 10.1"Color LCD Touch Screen
New interface design, reasonable layout and color matching
Pressure-Time waveform, Flow-Time waveform display on the same screen
Powerful monitoring and alarm functions
Comprehensive respiratory mechanics monitoring allows you to fully grasp the patient's respiratory status
HIGH-PRECISION VAPORIZER
Vaporizer can support low flow anesthesia as low as 0.2L/min and large flow anesthesia up to 15L/min.
Accurate output of concentrations under varying conditions of pressure, flow and temperature.
Support Selectatec Mounting type and Cagemount compatible
4 Kinds of Vaporizer for Choice: Halothane, Enflurane, Isoflurane and Sevoflurane
Fill-in type: Pouring
INTEGRATED BREATHING CIRCUIT
Integrated breathing circuit with APL valve, excellent tightness and safety.
Made of special materials, resistant to corrosion and high temperature.
Compact structure, no external pipelines, good mechanical compliance.
Impeller sampling is used at the exhalation end to avoid inaccurate monitoring of tidal volume due to water vapor condensation.
Drive bellows is not required to repalce when operating pediatric anesthesia.
Large volume of CO2 canister, single tank structure for more convenient in assembly.
TECHNICAL PARAMETERS
PART OF ANESTHESIA MACHINE
Main Body
High-strength engineering plastic rack, light, beautiful and corrosion resistant
Scope of Application:
Adult, Child
Gas Source
O2: 0.28~0.6MPa, N2O: 0.28~0.6MPa
Flow Meter
O2: 0.05~1.0L/min,1.1~10L/min
N2O: 0.05~1.0L/min,1.1~10L/min
O2-N2O Linkage and N2O Stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.16±0.02Kpa, the flow of nitrous oxide would be cut off.
Flow Rate of Rapid Oxygen Supply
25~75L/min
Low Oxygen Pressure Alarm
There will be sound alarm when the oxygen pressure < 0.2MPa
Vaporizer
It has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%.
Among Halothane,Enflurane, Isoflurane and Sevoflurane, one can be chosen for application as required by the customer.
Respiratory Circuit
Working mode: All-close, Semi-close, Semi-open
APL: ≤12.5 kPa
Respiratory Bellows
Bellows for adults and children
Tidal volume range:0~1500 ml
Light
Equipped with LED illumination, easy for observation
PART OF VENTILATOR
Display Mode
High-definition 10.1"TFT color LCD touch screen display, easy and convenient operation
Ventilation Mode
IPPV, SIPPV, SIMV, PEEP, SIGH, MANUAL
Ventilation Function
PEEP,SIGH, IRV
Ventilation Parameters
Tidal volume:50~1500 ml
Rate:2~99 bpm
SIMV rate:2~20 bpm
I:E:2:1~1:8
Inspiratory trigger pressure: -10~20 cmH2O
PEEP:2~20 cmH2O
Pressure range:5~60 cmH2O
SIGH:1.5 times the inspiratory time/ 100 times breath
Parameters For Ventilation Monitoring
Tidal Volume, Ventilation Volume, IPPV Rate, SIMV Rate, I:E, Peak Pressure of Airway, Pressure-Time Waveform, Flow Rate-Time Waveform, PEEP, Inspiratory Trigger Pressure (Average Pressure, FiO2 Oxygen Concentration, Battery Level)
Security Alarm System
Oxygen Concentration Alarm: Upper limit setting range:21%~99%,Low limit setting range:18%~80%
Airway Pressure Alarm: Upper limit setting range:5~60 cmH2O,Low limit setting range:0~50cmH2O
Per-minute Ventilation Volume Alarm: Upper limit setting range:1~20L/min,Low limit setting range: 0~19L/min
Tidal Volume alarm: Upper limit setting range:100~1500ml,Low limit setting range 0~1400ml
Sustained High Pressure Alarm: It will give alarm when stress have consistently been higher than 25 cmH2O for 15s.
Suffocation Alarm: It will give alarm when stress have consistently been higher than 10 cmH2O and tidal volume is less than 120ml for 15s.
Tube Escape Alarm: It will give alarm when stress have consistently been less than 2cmH2O for 15s.
Low Battery Level Alarm: It will give alarm when battery level is less than 14±0.5V
Negative Pressure Alarm: It will give alarm when airway stress has been less than 10cmH2O for 1s.
Power Supply
AC 220V 50Hz
Built-in Li Battery (Work at least for 8 hours)
Options
Mechanical Arms Bracket for Patient Monitor
ETCO2 monitoring