20kW 320mA Veterinary X Ray Machine Digital Type with Wireless Flat Panel
20kW 320mA Veterinary X Ray Machine Digital Type with Wired Flat Panel
20kW 320mA V Mobile Veterinary X Ray Machine Analog Type

20kW 320mA Veterinary X Ray Machine Digital Type Parameters
 
Power 20kW (can take clear images for the body no more than 35cm thickness )
Power supply Single-phase,220V 50/60HZ
(wire diameter>4mm², internal resistance<0.5Ω)
mA 10~320 mA
mAS 1~320Mas, stepping by R'10
KV 40~125kV, stepping by 1kV
Exposure time 0.003~6.3S adjustment: Increased
/reduced by 1mS each time
X-ray tube Chinese brands Mingwei M7110 are available or Toshiba tube for options .0.6-1.2mm double focus
Anode rotating speed/Anode heat capacity
2800prm/140kHU
Generator frequency 400kHz
Radiography table(W*L cm) Width: 70cm, length: 140/120cm (either)
urinary trough can be equipped with
Flat panel detector Imaging area 17*17 inches (or 14*17 inches) (wired and wireless)
Pixel size 140um
A/D conversion 16bits
Spatial resolution 3.6lp/mm
Software Veterinary software
Computer configuration Intel i5 processor; 8G memory, 2G discrete graphics card, 128G solid state drive + 1TB mechanical hard drive, PCI-E and Ethernet dual Gigabit network cable interface, R232 interface; 22.5-inch Dell professional small dot pitch monitor; operating system: win10
High Frequency Animal Hospital Clinic Medical Image System 20kw 320mA Veterinary Analogue Radiography X Ray MachineHigh Frequency Animal Hospital Clinic Medical Image System 20kw 320mA Veterinary Analogue Radiography X Ray MachineInstallation Instructions
1.X-ray room: 20m2 room is recommended.  2. Lead glass size recommended: 40*60cm or 60*80 cm
3. X-ray protection preparation: use barium sulfate powder or lead sheet for the wall of the room, and lead sheet for the ceiling;
4. A fan must be installed on the top to facilitate the discharge of ionized air
5. All surfaces of the x-ray room that people can reach need to be covered with lead sheet or barium sulfate powder. If it is the first floor, the ground does not need to be covered; if it is the top floor and will not polluted the environment, lead protection is not required.


 