Defibrillator with Monitor Aj-8000b (Biphasic Technology)

Certification: CE, FDA, ISO13485
Defibrillator Type: Manual, Synchronized, Asynchronized
out Put Waveform: Biphasic Technology
Energy Selection: 0, 20, 50,100,160,250,300,360 Joule
Charging Time: Maximum 8 Seconds to 360 Joules
Transport Package: Standard Export Packing
Customization:
Gold Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AJ-8000B
Specification
ISO; CE
Trademark
ANJUE
Origin
China

Product Description

Defibrillator
       (1)   Defibrillator type                Manual, Synchronized, Asynchronized,   
       (2)   Out put waveform                    Biphasic technology                                                                            
       (3)   Energy accuracy                     ∠+1%
    (4)  Energy selection              0, 20, 50,100,160,250,300,360 joule (nominal at a resistance of 50)
       (5)   Charging time                       Maximum 8 seconds to 360 Joules
(6)  Standard Adult/Pediatric Paddles   Reusable external adult paddles (pediatric paddles integrated)
           
Power requirements
       (a)   AC Power supply              110V, 60 Hz /220V, 50 Hz  
(b) Vehicle Voltage           DC 12V
 
Internal Battery Backup
       (1)   Battery type            Rechargeable lead-acid battery
       (2)   Charging time                Time-Minimum of 4 hours for full charging    
(3)  Battery charging      During AC Power Supply operation of the device.
(4) Charging /Low Battery Indication      Red LED                
(5) Battery Capacity        100% of the battery will provide 120 minutes of monitoring; and 30 discharges at 360 joules.
 
Display
LED Dimensions 10'diagonal
Type High resolution true-color graphic LED
 
ECG
ECG lead: I, II, III, AVR, AVL, AVF, V1~V6, GND
S-T segment analysis: -2.0~2.0mv
Arrhythmia analysis: yes
Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation
 
Respiration
Measurement method: Thoracic impedance
 
NIBP
Working mode: Manual/Automatic/stat (5 minutes)
Method: Automatic oscillation
Cuff type: standard Adult; optional Pediatric/Neonatal
 
Temperature
Measurement range 20~45ºC
Resolution 0.1ºC
 
Pulse Oximetry (SPO2)
Display :SPO2 value, pulse histogram, waveform, Pulse
Range: 0~99%for adult, pediatric and neonatal patients
Probe :Standard adult finger clip
Optional pediatric Y-type clip and neonatal wrap
 
Pulse range
Pulse range: 0-255bpm
 
Standard Configuration
 ECG/ RESP, /SPO2, /TEMP,/PR,/NIBP/DEFIBRILLATOR
 
Optional Parameter
Built-in Printer
 
Physical Characteristics
Main unit: Desktop
Dimensions: L410xW360xH260 mm
Weight: 13kg

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now