• Electronic Spirometer / Pulmonary Function Analyzer
  • Electronic Spirometer / Pulmonary Function Analyzer

Electronic Spirometer / Pulmonary Function Analyzer

Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Spirometer
Group: Adult
Medical Device Regulatory Type: Type 2
Trademark: Anjue
Origin: China
Customization:
Gold Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
MSA99

Product Description

Electronic Spirometer / Pulmonary Function Analyzer MSA99

Electronic Spirometer / Pulmonary Function Analyzer



This Portable Pulmonary Function Test (PFT) Equipment can be used to measure vital capacity (VC), forced vital capacity (FVC), Maximum Ventilation Volume (MVV). Measurement algorithm refers to the ITS, ERS standards of the American Thoracic Society (ATS)
Adopting pressure-flow sensor, sensitive, precise, easy to launder, clean and durable
All parameters can be displayed on the oversized screen(320x240), built-in memory can store maximum 300 cases of patient measurement results
The instrument can calibrate automatically, all English operation, more convenient to operate
110mm thermal printer built-in, can print out a clear clinical report, predicted value, measured value
Measurement of breathing time: VC time 50 seconds, FVC measuring time 25 seconds, MVV time 12 seconds, in favor of the coordination between patients and the device
Compact and flexible
 
Items Technique specification
Display Screen Diagonal line  5.7inches
Monochrome LCD
Resolution 320*240
Control Standard: UTILITY KEY,SVC KEY,FVC KEY,MVV KEY,PRINT KEY,10WORDS KEY, START KEY,STOP KEY
Light alarm
Measurement means Flow velocity detection: pressure gradient pneumatic flow sensor
Capacity detection: flow velocity integral
measuring range Capacity range: 0L ~ 9L
Flow velocity range: 0 ~ 14L / s
measurement accuracy  Capacity:
0L ~ 1.6L (± 50ml) 
 6L ~ 9L (± 3%) 
Flow rate: 5% or 0.2L / s 
Respiratory rate:
4 / 20 ~ / min (± 1 / min) 
 20 / 60 / min (error: ± 5%) 
measuring time limit and degree Vital capacity: every 50s, measuring 3 
 FVC: per second, 25s, measuring 3 
 The maximum ventilation volume: every 12 seconds, measuring 3 
Paper Recorder Method: dot matrix
Level Resolution Ration: 8 d/mmspeed 25mm/s
Uprightness Resolution Ration: 8 d/mm
Wave Channels: 1
Paper Width: 110mm1.97inches
Paper Length: 15m100inches
Formfeed Speed: 12.5,25 and 50mm/s±2
Power supply AC: 100V~240V
DC: rechargeable Nickel-metal hydride (NI-MH), 14.4-volt, 1.8 amp hour
Fuse 100V~240V ACF2A250V,5×20mm
Safety classification IEC60601-1 class I, type CF






 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now