ICU Ventilator Aj-2208 with Built-in Air Compressor

Product Details
Customization: Available
Type: Ventilator
Certification: CE, ISO13485
Gold Member Since 2011

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (8)
  • ICU Ventilator Aj-2208 with Built-in Air Compressor
  • ICU Ventilator Aj-2208 with Built-in Air Compressor
  • ICU Ventilator Aj-2208 with Built-in Air Compressor
Find Similar Products

Basic Info.

Model NO.
AJ-2208
Group
Adult
LCD Display
With LCD Display
Source
Oxygen
Kind
All Operation
Transport Package
Wooden Package
Specification
0.64cbm, 82kg
Trademark
ANJUE
Origin
Jiangsu

Product Description

Main technical parameters
Display mode                  
Japan Sharp 10.4" TFT color LCD screen display
Ventilation mode                
IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH,IMV, VCV, PCV
Ventilation parameters            
Tidal volume: 20~1500 ml
Rate:1~99 bpm
SIMV rate:1~20 bpm
I:E:4:1~1:8
Inspiratory trigger pressure :-1.0~2.0Kpa
PEEP:0~2.0Kpa
Pressure range:1.0~6.0Kpa
SIGH: 1.5 times the inspiratory time(70-150 adjustable)
Inspiratory platform:0~50%
 Parameters for ventilation monitoring     
Tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance, airway resistance, flow -volume loop, pressure-volume loop)
Monitoring of oxygen concentration : 21%~100%( To avoid Oxygen Toxicity)
Security Alarm System
Oxygen Concentration alarm:upper limit setting range 21%~100%                                 low limit setting range 10%~80%
Airway pressure alarm: upper limit setting range  0.3~6.0 kPa low limit setting range 0.2~5.0 kPa
Per-minute ventilation volume alarm: upper limit setting range  3.0~30L/min low limit setting range 1.0~10L/min
Sustained high-pressure alarm: It will give alarm when stress have consistently been higher than 2.5 kPa 
Suffocation alarm: It will give sound and light alarm if there is no tidal volume input for 15 seconds.
Power alarm
 Power:AC 220V±10%     50Hz±1Hz UPS, Storage battery
Mechanical Arms
Air Compressor

 