• Anesthesia Machine with Ventilator and with a Stable Concentration Output
  • Anesthesia Machine with Ventilator and with a Stable Concentration Output
  • Anesthesia Machine with Ventilator and with a Stable Concentration Output
  • Anesthesia Machine with Ventilator and with a Stable Concentration Output
  • Anesthesia Machine with Ventilator and with a Stable Concentration Output
  • Anesthesia Machine with Ventilator and with a Stable Concentration Output

Anesthesia Machine with Ventilator and with a Stable Concentration Output

Classification: Aneshesia Machine
Type: Aneshesia Machine
Certification: CE, ISO13485
Low Limit Setting Range: 1.0~10L/Min
Flow Meter O2: 0.1~1.0L/Min 1.1~10L/Min
Flow Rate of Rapid Oxygen Supply: 25~75L/Min
Customization:
Gold Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AJ-2103
Tidal Volume Range
0~1, 500 Ml
Transport Package
Standard Exporting Package
Specification
CE
Trademark
Anjue
Origin
Made in China

Product Description

 Anesthesia Machine with Ventilator and with a Stable Concentration OutputThe Ventilator adopts microcomputer control with high-definition 5.7" LCD display, integrating the functions of respiratory control and displaying the monitoring parameters. It is versatile in function and excellent in performance.
 The high-precision Vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose two kinds of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
 High-definition four-tube flowmeter, designed with stoppers for oxygen and nitrous oxide to control the output oxygen concentration.
 Reliable pneumatic transmission system.
 Economic and proper configuration of technologies, optional as required by the Customer.
 Modularized design and upgrading. Upgrading is available as required by the Customer.

TECHNICAL PARAMETERS
Part of Anesthesia Machine
Main body High-strength engineering plastic rack, light,
Beautiful and corrosion resistant
Scope of application adult, child
Gas source O2: 0.27~0.55MPa N2O: 0.27~0.55MPa
Flow meter O2: 0.1~1.0L/min 1.1~10L/min
N2O: 0.1~1.0L/min 1.1~10L/min
O2, N2O linkage and N2O Stopper
When using nitrous oxide, oxygen concentration>25%;
When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.
Flow rate of rapid oxygen supply 25~75L/min
Low oxygen pressure alarm There will be sound alarm when the oxygen
Pressure < 0.2MPa
Vaporizer it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%.
Among Halothane, Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.
Respiratory circuit working mode: All-close, semi-close, semi-open
APL: 0.5~7 kPa
Respiratory Bellows bellows for adults, bellows for children
Tidal volume range: 0~1, 500 ml

Part of Ventilator
Display mode High-definition 5.7" LCD screen display
Ventilation mode IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH
Ventilation parameters Tidal volume 50~1500 ml
Rate 2~99 bpm
SIMV rate 2~20 bpm
I: E 2: 1~1: 8
Inspiratory trigger pressure -1.0~2.0 kPa
PEEP 0~2.0 kPa
Pressure range 1.0~6.0 kPa
SIGH 1.5 times the inspiratory time
Parameters for ventilation monitoring tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure
Monitoring of oxygen concentration (21%~100%)
Security Alarm System
Oxygen Concentration alarm upper limit setting range (50%~100%)
Low limit setting range (15%~50%)
Airway pressure alarm upper limit setting range 1.0~6.0 kPa
Low limit setting range 0.4~2.0 kPa
Per-minute ventilation volume alarm upper limit setting range 3.0~30L/min
Low limit setting range 1.0~10L/min
Sustained high-pressure alarm it will give alarm when stress have consistently
Been higher than 2.5 kPa
Suffocation alarm it will give sound and light alarm if there is
No tidal volume input for 15 seconds
Power alarm
Power AC 220V± 10% 50Hz± 1Hz
(UPS, Storage battery)
(Mechanical Arms)
(End-expiratory CO2 monitoring)
*Items within brackets are optional.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now