AJ-2103 Anesthesia Machine, with its ergonomic design, integrates a concise and smooth structure and high mobility. The microcomputer-controlled Ventilator adopts exported sensors and other components. Its scientific and proper design as well as rigorous production process is what demonstrates the inner quality of Anjue products: mechanical ventilation is made secure and visible by the folded respiratory bellows, and the security of air supply is guaranteed by pneumatic transmission and measurement system. With multiple modern technologies applied, the Anesthesia Machine is both outstanding in performance and versatile in functions.

TECHNICAL PARAMETERS
Part of Anesthesia Machine
*Main body                 High-strength engineering plastic rack, light,
beautiful and corrosion resistant
*Scope of application          adult, child
*Gas source                 O2: 0.27~0.55MPa    N2O: 0.27~0.55MPa
*Flow meter                 O2:  0.1~1.0L/min     1.1~10L/min
N2O: 0.1~1.0L/min     1.1~10L/min
*O2, N2O linkage and N2O Stopper
  When using nitrous oxide, oxygen concentration>25%;
  When the oxygen pressure<0.2Kpa, the flow of nitrous oxide would be cut off.
*Flow rate of rapid oxygen supply   25~75L/min
*Low oxygen pressure alarm    There will be sound alarm when the oxygen
pressure < 0.2MPa
*Vaporizer                  it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5 vol%.
Among Halothane,Enflurane,Isoflurane and Sevoflurane,two can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available.
*Respiratory circuit            working mode: all-close, semi-close, semi-open
                            APL: 0.5~7 kPa
*Respiratory Bellows          bellows for adults, bellows for children
tidal volume range:0~1,500 ml
 
Part of Ventilator
*Display mode               High-definition 5.7" LCD screen display
*Ventilation mode            IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH
*Ventilation parameters        Tidal volume         50~1500 ml
Rate                2~99 bpm
SIMV rate           2~20 bpm
I:E                 2:1~1:8
Inspiratory trigger pressure  -1.0~2.0 kPa
PEEP                0~2.0 kPa
Pressure range        1.0~6.0 kPa
SIGH           1.5 times the inspiratory time
*Parameters for ventilation monitoring  tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure
*Monitoring of oxygen concentration  (21%~100%)
*Security Alarm System
Oxygen Concentration alarm    upper limit setting range   (50%~100%)
low limit setting range    (15%~50%)
Airway pressure alarm         upper limit setting range   1.0~6.0 kPa
low limit setting range    0.4~2.0 kPa
Per-minute ventilation volume alarm   upper limit setting range   3.0~30L/min
low limit setting range    1.0~10L/min
Sustained high-pressure alarm       it will give alarm when stress have consistently
been higher than 2.5 kPa
Suffocation alarm             it will give sound and light alarm if there is
no tidal volume input for 15 seconds
Power alarm
* Power                       AC 220V±10%     50Hz±1Hz
                           (UPS, Storage battery)
*(Mechanical Arms)
*(End-expiratory CO2 monitoring)
*Items within brackets are optional.