New Dialysis Center Popular Dialysis Machine

Certification: CE, FDA, ISO13485
Application: Chronic Renal Failure and Other Blood Purification
Size & Weight Size: 380mm*400mm*1380mm (L*W*H)
Area: 500*520 Mm
Weight: 88kg
Power Supply: AC220V, 50Hz / 60Hz, 10A
Customization:
Gold Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
AJ-2008A
Input Power
1500W
Back-up Battery
30 Minutes (Optional)
Water Input Pressure
0.15 Mpa~0.6 Mpa, 21.75 P.S.I.~87 P.S.I.
Water Input Temperature
10 Celsius Degree~30 Celsius Degree
Working Environment
10 Celsius Degree~30 Celsius Degree
Transport Package
Standard Export Packing
Specification
ISO; CE; FDA
Trademark
ANJUE
Origin
China

Product Description

Function:
Hemodialysis, Isolated Ultrafiltration, Sequential Ultrafiltration, Hemoperfusion, Plasma exchange (optional).

Technical Features:
1. Multrifunction, individual therapy.
2. The advanced volume balance control system enables accurate control of ultrafiltration.
3. The combination of sodium profile and ultrafiltration profile effectively avoids comlications: Low blood pressure and electrolyte unbalance.
4. Relibility and safety are ensured by a dual-control supervising system.
5.
Function Features:
1. Sodium and UF profiling provide individual treatment for patients.
2. Convenient program of sequential therapy and dialysis with variational sodium.
3. KT/V calculation function evaluates the sufficiency of dialysis.
4. The special hemoperfusion mode reduces the time for selftest and the consumption of water and concentrates in normal dialysis machines.
5. Can provide the isolated dialysis.
6. Back-up power supply for 30 min after electricity off.
ITEM SPECIFICATION
Dimensions (W x H x L) 850 × 840×1660 MM
Gross Weight Aprox. 140 Kg
Power Supply AC220V, 50~60HZ
Connected Load £2000VA
Water Supply Pressure Range :0~8.0BAR, Temperature Range:0~35 degree
Venous Pressure Working Range -700~+800mmhg, Accuracy±10mmhg
ArterialPressure Working Range -700~+800mmhg, Accuracy±10mmhg
Transmembrane Pressure Working Range -700~+800mmhg, Accuracy±10mmhg
BloodFlow Range 0~700ml/Min
DialysateFlow Range 0~300~500~800ml/Min (Adjustable)
SubstitutionFlow Range 0~25L/H
DialysateTEMP Working Range 30~41degree ,Accuracy±0.1degree
HeparinPump Working Range 0~10 ml/H,Accuracy±0.1ml/H
ConductivityWorking Range 10~20 ms/cm Accuracy±0.1ms/cm
Air Detector Detecting³0.02ML/Single Bubble Detecting
Blood Leak Detector Detecting blood leak ≥0.35mL/min (HCT 32%)
Hot Rinse 85degree
Clean/ Disinfection Decalcification: Rinse, citric acid
Thermal Disinfection: Hot water or citric acid
Chemical Disinfection: Sodium hypochlorite or peracetic acid

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now