ICU Ventilator with Air Compressor, ICU Ventilator, Ventilator with Air Compressor manufacturer / supplier in China, offering Ce Approved ICU Ventilator with Air Compressor (AJ-2208), Best Selling High Frequency Electrosurgical (AJ-S900E), Best Selling Cold Light Shadowless Operating Lamp and so on.

(/ )

Supplier Homepage Product Anesthesia Machine & Ventilator Ce Approved ICU Ventilator with Air Compressor (AJ-2208)

Ce Approved ICU Ventilator with Air Compressor (AJ-2208)

FOB Price: US $5,660 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $5,660/ Piece
Get Latest Price
Port: Shanghai, China
Transport Package: Standard Export Packing
Payment Terms: T/T, Western Union, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: AJ-2208
  • Pressure Range: 1.0~6.0kpa
  • Rate: 1~99 Bpm
  • Trademark: ANJUE
  • Origin: China
  • Certification: CE, ISO13485
  • Simv Rate: 1~20 Bpm
  • Tidal Volume: 20~1500 Ml
  • Specification: ISO; CE
Product Description
ICU Ventilator AJ-2208 with Air Compressor
(Constant Volume and Constant Pressure)

Main technical parameters
*Display mode
High-definition 10.4" TFT color LCD screen display
*Ventilation mode
IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH, IMV, VCV, PCV
*Ventilation parameters
Tidal volume: 20~1500 ml
Rate: 1~99 bpm
SIMV rate: 1~20 bpm
I: E: 4: 1~1: 8
Inspiratory trigger pressure: -1.0~2.0Kpa
PEEP: 0~2.0Kpa
Pressure range: 1.0~6.0Kpa
SIGH: 1.5 times the inspiratory time(70-150 adjustable)
Inspiratory platform: 0~50%
*Parameters for ventilation monitoring
Tidal volume, ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, average pressure, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, Inspiratory platform (autonomous inspiratory rate, lung compliance, airway resistance, flow -volume loop, pressure-volume loop)
*Monitoring of oxygen concentration: 21%~100%
*Security Alarm System
Oxygen Concentration alarm: Upper limit setting range 21%~100% low limit setting range 10%~80%
Airway pressure alarm: Upper limit setting range 0.3~6.0 kPa low limit setting range 0.2~5.0 kPa
Per-minute ventilation volume alarm: Upper limit setting range 3.0~30L/min low limit setting range 1.0~10L/min
Sustained high-pressure alarm: It will give alarm when stress have consistently been higher than 2.5 kPa
Suffocation alarm: It will give sound and light alarm if there is no tidal volume input for 15 seconds.
Power alarm
* Power: AC 220V± 10% 50Hz± 1Hz UPS, Storage battery
*Mechanical Arms